Guaranteed Safe Checkout

A programmable chemical automation system shall be furnished for the continuous monitoring of the followingpool and spa parameters: pH, disinfectant levels, temperature, and flow switch. The controller shall be capable ofcontrolling pH and disinfectant. Installation of the system shall be as specified by the manufacturer and noexceptions shall be taken. The water monitoring software and programmable controller systems as specified belowwill be provided. A factory authorized representative shall provide training to the owner. 

 

Standard Features:

  • Includes flow cell, flow switch, pH and ORP chemical sensors
  • Programmable enabling of proportional feed
  • Programmable set points for the pH and ORP levels
  • Programmable chemical feed cycle
  • Programmable selection of acid or base feed for pH control
  • Calibration of pH, ORP and temperature
  • Flow cell with built-in flow switch and sampling port

 

Acu-Trol AT-8 Features:

Programmability 

  • Proportional Feed
  • Feeder ON and OFF cycles
  • pH and ORP set point
  • ORP & pH calibration
  • Temperature calibration
  • Acid feed
  • Base feed
  • Password Protected
  • LED Alarm Indicator

Flow Cell

  • Convenient inlet and outlet ports
  • Built-in flow switch to disable feed in no flow conditions
  • Chemical injection ports
  • Sample port for testing
  • Clear acrylic viewing jar

Sensors

  • pH and ORP
  • Temperature
  • Flow

•  The system shall be a Pentair Commercial Aquatics™ Acu-Trol AT-8 controller or a technically equal system capableof providing continuous automatic monitoring of temperature and control of water chemistry. 

•  Sensors: The controller shall be capable of controlling sensors for the measurement and control of the watersystem. The controller shall have the ability to calibrate all sensor inputs. The controller shall provide separateelectrical isolation for the sensors. Controllers not providing separate electrical isolation for the following sensorsare not considered equal. The controller shall be capable of measuring using the following sensors: ORP: thesensor range shall be 450 to 999 mV with a 1 mV resolution, pH: the sensor range shall be 0.1 to 9.9 mV with a0.1 resolution, Temperature: the sensor range shall be 15 to 150 degrees Fahrenheit with a 1 degree resolution,Temperature can be set to read in Fahrenheit or Celsius, Flow Switch: the sensor shall detect an open orclosed condition.•  Flow Cell: The flow cell shall include two (2) sensors, one (1) in-line filter, one (1) safety flow switch, and one (1)sampling valve for water testing. The flow cell shall be transparent allowing for visual inspection of the sensors.The flow cell shall also include a valve at the inlet and outlet that may be used to adjust the flow or to stop theflow for probe cleaning or removal. The flow cell shall have two (2) extra plumbing ports. The flow cell shall bedesigned in such a way that it is not possible for the sensors to be exposed to air. The flow cell shall have aremovable reservoir for cleaning.•  Relay Output: The controller shall be capable of controlling two (2) relays. The controller shall provide at aminimum five (5) amps of current for any group of two (2) relays. Adjustable DPST and DPDT Relays: The sanitizerrelay shall supply either service voltage, 24 VAC, or act as a dry contact. The relay ratings are 5A at 250 VAC. The 24VAC current rating is 0.25A. The pH relay shall supply service voltage. The relay ratings are 5A at 250 VAC. DefaultRelay Setups: The controller shall provide means for initially programming any relay to factory defaults.•   Enclosure: The controller’s enclosure shall have the rating of NEMA 4X. The controller’s dimensions areapproximately 7-5/8” x 5-5/8” x 2-7/8”.•   Interface: The controller shall be equipped with a 16 by 2 character display as the customer interface. This LCDdisplay shall be backlit and automatically light when a button is touched, and shall remain lit for a fixed five (5)minutes of time. After five (5) minutes of inactivity the display will go to dim mode. The dim mode display is stillvisible in poor lighting conditions. Controllers without a dim mode shall not be considered equal. The controllershall include a four button keyboard.•   Relay Programming: The controller shall be equipped with a detailed reset menu and shall allow for the resettingof one or all relays back to the original factory defaults. The controller’s relays shall be capable of being configuredto control the following: Limiting the maximum length of time a relay shall be ON, Simultaneous Chemical FeedLockout, The controller shall not adjust the pH while the disinfectant is in a feed cycle, ORP lockout if pH is above aset limit, On time proportional feed Manually turn ON a relay for the set feed time, Control primary disinfectant.•   Setup, Calibration, and Data Recording: In the absence of power, the controller shall retain all setup informationand calibration data for up to 7 years. The data shall be viewable on the front panel on the AT8. The controller shallallow data recording intervals to be set by the operator with a range of 1 minute to 12 hours. The Controller shallhave the ability to store 2,048 measurement lines. Controllers that do not allow at least 2048 lines of data will notbe considered equal.•   Alarms: The controller’s alarms shall have programmable upper and lower limits. The controller’s alarms shall beactivated by any relay or sensor measurement. The controller shall alert operator of alarm conditions with RED LEDand flashing name.•   Security: The controller shall be capable of managing one (1) level of security accessible via one (1) password. Thepassword may contain up to six (6) digits. When unattended, the controller shall reset to secure mode after thedisplay back light returns to dim mode.•   Base Bid Options: The controller for the base bid options shall include pH, ORP, and temperature sensors, andflow cell.•   Warranty: The controller shall be covered by a standard manufacturer warranty of one (1) year. All pH and ORPsensors will be covered by a two (2) year warranty. Flow Cell will be covered by a one (1) year warranty. This warrantyextends to the original retail owner only, beginning on the date of installation, and is not enforceable by any otherparty. Proof of purchase and/or date of installation will be required to execute a warranty claim.•   Warranties by Others: Some products incorporate components manufactured by other manufacturers. Some of theseprovide warranties in addition to the warranty provided herein. In all such cases, a copy of that warranty will beprovided with the product. To the extent protection provided under any such third party warranty exceeds the LimitedWarranty provided herein, the Customer will have to look to that manufacturer for the additional warranty protection.